Field of application
The Deltapilot FMB70 with the condensate resistant Contite measuring cell and two-chamber housing is typically used in the process and hygienic applications. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. The integrated HistoROM/M-DAT data module makes management of process and device parameters easy. Designed according to IEC 61508 for use in SIL3 safety systems.
For level and/or pressure measurement.
-
Process connections: Threads, flanges and hygienic connections
-
Temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)
-
Measuring range: 0.1 to 10 bar rel. (1.5 to 150 psi)
-
Accuracy: ±0.075%
-
International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvals